Subj : SEXPOTS - Pulling my hair out... :) To : cafarmer From : Digital Man Date : Mon Jun 10 2024 05:05 pm Re: SEXPOTS - Pulling my hair out... :) By: cafarmer to Digital Man on Mon Jun 10 2024 12:26 pm > I tried both AT&C1 (it was a suggested init string for the optima AT&C1&D2) > and ATC1. The modem didn't like AT&C1 - Error. Both modems didn't that AT&C1 or just the 1200? If the modem doesn't accept AT&C1, then you'll need to set IgnoreDCD = TRUE in the sexpots.ini file used for that modem. > I cannot find the manual for the HSM 1200. But I did find the manual for the > HSM 300 and a General Smartmodem Guide. > > D.5.1 Using the CD line > If you are confident of the communications environment and cabling > requirements, and have access to the RS-232 signal status, then monitoring > the CD line is the easiest carrier loss detection method to implement. This > requires &C1 to be programmed at setup time, or be stored in the modem as > the value recalled on reset or powerup. > However, this is the most restrictive and risky choice. It requires a > properly wired cable and support of &C1 by the modem's command set or proper > DIP- switch settings. Wouldn't the HSM 300 be older than the 1200? I'd be very suprirsed if an older (300bps?) modem supported AT&C1 while the newer modem (1200bps?) did not. > Since there may be some confusion on my part between ATC1 and AT&C1, I'm not > exactly sure if this text applies now: > > Cn - Controls ¨Smartmodem's¨ transmitter carrier; i.e.,¨signal sent > when¨ calling, answering or ¨connected to a distant modem. > Default C=1 > n = 0 Transmitter Off > n = 1 Transmitter On > > So this was for the HSM 300 that came before the HSM 1200... I would be > surprised if most of the commands were not supported in the HSM 1200. > > ATC1 = OK (not sure what this does. ATC? returns 000) > AT&C1 - ERROR Weird. Anyway, telling SexPOTS to ignore DCD should work around *that* modem issue. -- digital man (rob) Sling Blade quote #4: Doyle: wimpy-ass kids or mental retards.. she got one of each livin' with her. Norco, CA WX: 78.5øF, 55.0% humidity, 12 mph W wind, 0.00 inches rain/24hrs .