Subj : Error with Weather program To : Steven Sheeley From : KenDB3 Date : Thu Sep 29 2016 01:04 pm Re: Error with Weather program By: Steven Sheeley to KenDB3 on Wed Sep 28 2016 08:44 pm Ke>> If that is not it, then some Debug info might be helpful here. Ke>> In Synchronet, change your LogLevel to be Debugging. This should Ke>> generate a Debug message in your Synchronet Control Panel and Logs Ke>> that has the actual String sent to wunderground.com and the error Ke>> the API kicked back (hopefully). SS> ; Highest log level to actually log/print (ignore all higher/less-severe SS> log entries): ; This log level may be overridden for each server/service SS> ; Supported log levels in decreasing severity (ala syslog): SS> ; Emergency, Alert, Critical, Error, Warning, Notice, Informational, SS> Debugging SS> LogLevel=Debugging SS> Logging level is set to debug and this is what I got from SS> @ 20:42 Wed Sep 28 2016 Node 1 SS> @+ Telnet SplitInfinity [192.168.1.28] SS> ++ (0001) Buckaroo Banzai Logon 0 - 11 SS> X- Buckaroo Banzai running external program: Bullshit SS> X- Buckaroo Banzai running external program: Your Local Weather SS> /O SS> @- 20:43 T: 0 R: 0 P: 0 E: 0 F: 0 U: 0k 0 D: 0k 0 SS> From the log 092816.log in my ./sbbs/data/logs directory. SS> Is that what you are looking for? Steven, I'm replying here, but I also read your email to me, but when I tried to reply back, I noticed your domain for your email was coming up as your private IP (192.168.x.x), so I am guessing you didn't get the email. SS> I think I've tracked down the issue. In SBBS 3.16c the door worked SS> perfectly when I conecnted locally. My BBS is on my unroutable adres SS> 192.168.1.28 abd my lcoal machine sits on the same networl The door SS> used to give the GEO-IP address of the Public address of my BBS when SS> I netered locally and it was correct. SS> Now, SBBS, is sending the un-reoutable IP address in the string. SS> I included all the debug into in my follow up post on Dove-Net SS> Here's the info from my SBBS.INI SS> [Global] SS> ; Override system address for this instance (optional): SS> HostName=infinity.synchro.net SS> ; IP address of network interface to bind to (defaults to ANY/ALL interfaces): SS> Interface=0.0.0.0 Is this the log info you mentioned adding? Because when I emailed you, I was advising that there is better log info directly in the SBBS Control Panel. I took some screen shots. This is the program running normally: http://bbs.kd3.us/screenshots/Synchronet-Windows-Control-Panel.png This example is if there is an error, there is Debug info you can grab: http://bbs.kd3.us/screenshots/Synchronet-Windows-Control-Panel-with-error.png I think I know what's going on, and you probably can do an easy fix on your end. But I want to see the Debug to see whether it is something that can be avoided with a code fix in the app. ~KenDB3 --- þ Synchronet þ KD3net-Rhode Island's only BBS about nothing. http://bbs.kd3.us .