Subj : 811H problem, please read To : ALL From : Alan Beck Date : Thu Oct 11 2018 10:05 am Hi, I put a pair of 572B tubes in my AL-811 amp and they died. One went to a plate current of 600 ma and the other 75 ma. Anyways, DX engineering tubes are coming. I checked all my 572B tubes one at a time and selected the best I could for the amp. The worst case sceneria was 75 ma. Here goes. 600 ma 150 ma 85 ma 75 ma. Am I going to trash my amp or will the output just drop? It's holding at 500 watts right now. For 100 watts in. So, should I leave well enough alone or should I only the 2 tubes in there as soon as they arrive? If one fails short could that take my amp out? Best 73, Alan VY2XU --- WinPoint Beta 5 (359.1) * Origin: Original WinPoint Origin! (1:229/426.36) .