(C) PLOS One This story was originally published by PLOS One and is unaltered. . . . . . . . . . . A parsimonious model of blood glucose homeostasis [1] ['Eric Ng', 'Ontario Tech University', 'Oshawa', 'Ontario', 'Klick Applied Sciences', 'Toronto', 'Jaycee M. Kaufman', 'Lennaert Van Veen', 'Yan Fossat'] Date: 2022-08 The mathematical modelling of biological systems has historically followed one of two approaches: comprehensive and minimal. In comprehensive models, the involved biological pathways are modelled independently, then brought together as an ensemble of equations that represents the system being studied, most often in the form of a large system of coupled differential equations. This approach often contains a very large number of tuneable parameters (> 100) where each describes some physical or biochemical subproperty. As a result, such models scale very poorly when assimilation of real world data is needed. Furthermore, condensing model results into simple indicators is challenging, an important difficulty in scenarios where medical diagnosis is required. In this paper, we develop a minimal model of glucose homeostasis with the potential to yield diagnostics for pre-diabetes. We model glucose homeostasis as a closed control system containing a self-feedback mechanism that describes the collective effects of the physiological components involved. The model is analyzed as a planar dynamical system, then tested and verified using data collected with continuous glucose monitors (CGMs) from healthy individuals in four separate studies. We show that, although the model has only a small number (3) of tunable parameters, their distributions are consistent across subjects and studies both for hyperglycemic and for hypoglycemic episodes. We present a model of glucose homeostasis that consists of an equation of the mass-action-kinetics type for glucose levels and a closed propotional-integral control loop. The control loop models the aggregate effect of all physiological components of homeostasis, such as the production and uptake of insulin and glucagon. We study the model as a smooth, planar, dynamical system and show that its solutions are bounded for parameter values that correspond to healthy individuals. We then fit the model parameters to datasets obtained with continuous glucose monitors in four different studies, and show that they have structured distributions for individuals across a healthy population. Data Availability: All blood glucose data used in this study are publicly available. Data in the Klick Pilot Study and Klick Follow-up Studies can be accessed through sections S1 and S2 Data respectively. The data of the Stanford study can be obtained via the following URL: https://doi.org/10.1371/journal.pbio.2005143.s010 . Introduction In the 1920s, Walter Cannon condensed a plethora of observations and ideas of early physiologists into the concept of homeostasis, i.e. the automated regulation of conditions of the human body, such as temperature, blood pressure and heart rate [1, 2]. This regulation serves to counteract disturbances from outside the body and keep its internal conditions in their safe operating range. While a monumental leap forwards philosophically, the concept remained largely qualitative in nature. Cannon carefully based his reasoning on observational evidence, but the latter is often anecdotal or derived from very small-scale experiments with Cannon himself or members of his lab as subjects. Nonetheless, his hypotheses on homeostasis were tantalizingly close to a quantitative description. For instance, he posed that “If a state remains steady it does so because any tendency towards change is automatically met by increased effectiveness of the factor or factors which resist the change”—a notion begging to be translated into a mathematical model. It was not until the 1940s, however, that a connection was made to the theory of feedback control. Particularly prolific in making this connection was Norbert Wiener, who devoted multiple sections of his book on Cybernetics to feedback control in human physiology [3]. From similarities between physiological and servo-mechanical feedback control, Wiener derived several interesting ideas on the mechanism of homeostasis and how its breakdown is associated with pathological states such as involuntary tremors. Over the two decades after the publication of Wiener’s book, the study of homeostasis became more firmly grounded in mathematics and experiment. Examples include the work of Corson et al. [4] on body water regulation, that of Stolwijk and Hardy [5] on body temperature and that of Powell [6] on plasma calcium regulation. Probably the most active topic of research, however, was the regulation of the blood glucose concentration. The malfunction of this particular feedback subsystem is associated with diabetes. The incidence of type-2 diabetes in the USA doubled in the 1960s [7] and this rapid rise likely explains the research focus of many physiologists, physicists and biochemical engineers entering the new field of homeostasis modelling. The quest to gain a better understanding of glucose homeostasis is ever more urgent, as diabetes now affects more than 30 million people in the USA alone (over 9% of the population), while another 84 million Americans have prediabetes [7, 8]. The steady progress in glucose homeostasis modelling, from reasoning by analogy to quantitative, predictive theory, can be explained in terms of major advancements in three directions. First is the gathering of data. Experiments were designed to unveil the interplay of glucose and regulatory hormones like insulin and glucagon, both in humans and in other mammals. An example of early work is that by Metz [9], who measured the production of insulin in response to artificially increased or reduced glucose levels in dogs. A few years later, Burns et al. [10] was one of several groups to design a continuous blood glucose monitor that could be used for a number of hours on a human subject in clinical setting. They used the data to model the oral glucose challenge, in which a subject drinks a calibrated amount of glucose after fasting, and the recovery of normal blood glucose levels is monitored. Second is the formulation of mathematical models. Informed by the data that were becoming available, various models, both of the innate glucose dynamics and of the feedback through hormones, were formulated and tested. Initially, mostly linear models were considered, for instance by Bolie [11], who used the data of Metz [9] to estimate parameters such as the rate constants of glucose removal and insulin production. Similar results were obtained by Ackeman et al. [12], who focused on the oral glucose challenge. Apparently frustrated by the sparsity of available data, they revisited the parameter fitting a few years later, finding good agreement with continuous glucose measurements as well [13]. Bergman et al. [14] systematically compared several linear and nonlinear models, the nonlinearity appearing in the interaction of insulin and glucose. They concluded that the action of insulin on elevated glucose levels is best described by a product of the respective concentrations, akin to mass-action kinetics. This feedback mechanism is now widely used in glucose control models, including ours presented in this paper. Third is the availability of digital computers. While, in the early 1960s, Bolie [11] built his own analogue computer especially for the purpose of producing numerical predictions with his model, aptly called the “Hormone Computer”, a decade later digital computers were rapidly becoming more accessible and useful, as demonstrated, for instance, by the work of Ceresa et al. [15] and Gatewood et al. [13]. Even by the standards of 1970s digital computing, time-stepping glucose homeostasis models in the form of small systems of ordinary differential equations was a light task. The difficulty lay in the computational cost of systematically exploring parameter space to find physiologically sound behaviour—a process called conformation by Gatewood et al. [13] that would today be considered a form of data assimilation. Indeed, the number of simulations one needs to run to gain a comprehensive overview of model behaviours grows exponentially with the number of parameters to be tuned, such as rate constants and baseline glucose and hormone concentrations. For a model with two variables and four parameters, like Bergman’s preferred minimal model [14], we can estimate that conformation of a single peak in glucose concentration must have cost at least one hour on the equipment available at the time, like the IBM System/360 Model 50 used by Ličko and Silvers [16]. In summary, by the 1980s various models glucose homeostasis had been developed and tuned to measured data with the aid of computational algorithms. As a result, much insight was gained in the hormonal regulation of blood glucose and quantitative estimates of, for instance, insulin sensitivity [14] and disappearance rate constants of glucose and insulin [16] were obtained. A more ambitious goal, formulated already by Gatewood et al. [13] is to use the tuned parameters as diagnostic tools. Since the model parameters quantify the regulation mechanism itself, rather than the glucose levels it produces, they could conceivably provide an indication of where a test subject stands on the scale from healthy to pre-diabetic and fully diabetic. While not feasible with the data acquisition and processing techniques of the 1970s, in recent years this goal has come within reach because of rapid progress in the three directions discussed above. Most importantly, continuous glucose monitors (CGMs) were developed. CGMs consist of a tiny needle, inserted in the upper arm and connected to a lightweight electronic device that is held in place with adhesive tape. Measurements are taken at fixed intervals and can be read wirelessly by a hand-held receiver. The needle usually causes little or no discomfort and can be worn during every day activities. Thus, we can now observe the complete feedback system at work. The modelling of these data requires a closed-loop control approach. In contrast, the models mentioned above are open-loop in the sense that, rather than a two-way interaction between glucose and regulatory hormones—or a proxy for those—they contain input terms that represent the injection of glucose or regulatory hormones in clamp or bolus experiments. One might say that pioneers like Bolie, Ackerman and Bergman approached the problem like an electrical engineer would probe a component of an electrical circuit: they isolate it and present it with a series of controlled inputs and measure the response. Closed feedback modelling is more similar to observing the component as it is playing its part in the circuit, unable to manipulate its input yet assuming it is, in part, determined by its output. Finally, comformation of mathematical models can now be done on the fly on a device as small as a smart watch so that diagnostics may be presented immediately upon the appearance of irregularities. Various authors have recently explored the use of mathematical models conformed to CGM data, often focusing on type-2 diabetes patients (Goel et al. [17], Gaynanova et al. [18] and Bartlette et al. [19]). The model we present and validate here can be considered, in the words of Wiener, a “white box” model. It is designed to reproduce the correct output, i.e. blood glucose concentration, for given input, in this case glucose released from digestion of food. It comprises only two variables: the deviation of the glucose concentration from a set point and a proxy for all control mechanisms. Thus, we do not model any specific pathway of control or hormone, only their aggregate effect. This idea is similar to that of “reign control” by Saunders et al. [20], who presented a closed-loop model in which insulin and glucagon concetrations are modelled separately. Our control variable is determined both by the instantaneous glucose concentration and by its recent history, the weight of past glucose concentrations decreasing exponentially with the delay. This “distributed delay” approach was proposed by Palumbo and De Gaetano [21]. Thus, our model contains three tunable parameters: the coefficients of the contributions of the instanteneous and the past glucose concentrations and the time scale of the distributed delay. To the best of our knowledge, this model is the most parsimonious among closed feedback models—Saunders et al. [20], for instance, included three variables and six parameters while Palumbo and De Gaetano [21] included four variables and six parameters and Goel et al. [17] use two variables and seven parameters. Since our model takes the form of a mildly nonlinear, planar dynamical system, it is susceptible to standard analysis. The first goal of this work is to establish that our model has the following desirable properties for physiologically admissible parameter values: It has a unique equilibrium solution which is asymptotically stable. This equilibrium can be though of as the target of the homeostatic control and it has a glucose concentration within the safe operating range. No time-periodic solutions can arise for constant input. Such solutions would correspond to potentially damaging, sustained oscillations of the blood glucose level. For variable input within reasonable bounds, the model glucose concentration and control variable remain bounded and the maximal glucose concentration lies at the high end of the safe operating range. Thus, our model has the properties one expects from a healthy homeostatic control system. The second goal of this work is to validate the model with CGM data of healthy individuals from three different studies using two different glucose monitors. Klick Pilot Study. This study was conducted at Klick Health and had 42 subjects, recruited locally in Toronto, Canada [22]. Preliminary results from this study were reported in van Veen et al. [23]. Klick Follow-up Studies. These studies were conducted at various sites in India and had 146 subjects in total [24, 25]. Stanford Study. Results from this study were reported by Hall et al. [26] and the CGM data for 36 subjects were made publically available. All Klick studies use the Freestyle Libre Flash Glucose Monitoring System (Abbott Laboratories) while the Stanford study used the Dexcom G4. We will establish, that the parameters of the tuned models are consistent across the different study groups, in the sense that they fall under distributions that appear to be Gaussian and independent of the equipment used or demographics of the test subjects. Thirdly, we will investigate data and model results for hypoglycemic episodes, i.e. excursions to glucose levels below the baseline. This is an extension of the model used by van Veen et al. [23], which only describes excursions above the base line. Hypoglycemic episodes have received relatively little attention in the literature. Palumbo and De Gaetano [21] simulated hypoglycemic conditions in their closed-loop model but did not conform the it to measured data. Data-based approaches have mostly been statistical in nature and aimed at type-2 diabetes patients, e.g. Yang et al. [27]. Finally we will demonstrate that, owing to the parsimony of the model, the conformation of parameters to segments of CGM data can be performed in seconds on a mid-range laptop computer. The inputs to this procedure are the raw CGM data, often with missing and corrupted measurements, and the output is a list of tuned parameters, one set for each detected peak or trough. While, in the current work, we focus on the validation of our model for healthy subjects, this pipeline of data acquisition, feature extraction and parameter conformation has the potential grow into a cheap, non-invasive, online diagnostic tool once the impact of early-onset diabetes on the model parameters is known. [END] --- [1] Url: https://journals.plos.org/digitalhealth/article?id=10.1371/journal.pdig.0000072 Published and (C) by PLOS One Content appears here under this condition or license: Creative Commons - Attribution BY 4.0. via Magical.Fish Gopher News Feeds: gopher://magical.fish/1/feeds/news/plosone/